Journal des techniques de chromatographie et de séparation

Journal des techniques de chromatographie et de séparation
Libre accès

ISSN: 2157-7064

Abstrait

Quantification of Cilostazol and Telmisartan in Combination Using Risk Profile and Uncertainty Contour: A Contemporary Validation Approach

Dharmendra D, Karan M, Bhoomi P and Rajshree CM

Risk profile and uncertainty estimation are the two major and important parameter that need to be carried out during the development of pharmaceutical process, to obtain reliable results. The conventional method validation schedule needs to be improvised so as to certify extraordinary method reliability to measure quality feature of a drug product. Risk profile assessment, expanded uncertainty and combined standard uncertainty in the analysis of cilostazol and telmisartan in combined tablet dosage form were studied in this research work. RP-HPLC method was validated in our laboratory as per ICH guideline and risk profile assessment has been outlined including uncertainty estimation using the cause-effect approach. In the course of validation, the calibration model found to be impregnable when encountered with lack of fit test and Levene’s test. In uncertainty major contribution is due to sample concentration and mass. The proposed research work clearly demonstrate the application of theoretical concept of calibration model tests, relative bias, risk profile and uncertainty in the methods used for analysis in drug discovery process.